Filtered generated 99 hits.
-
2014:20 An evaluation of high-temperature creep of zirconium alloys: data versus models
In this report Dr Massih presents correlations for creep in different phases of zirconium alloys and also presents a general solution to the difficulty of accurately describing the material properties in phase transition for several zirconium alloys. Based upon superplasticity relations, models are adapted to fit with experimental data for materials in transition regions. The creep models are...
Content type: Publications -
2014:19 Evaluation of the Halden IFA-650 loss-of-coolant accident experiments 5, 6 and 7
The analytical tools, which are fuel rod computer codes, that Quantum Technologies AB use and develop, contain models of several of the phenomena that are acting on the nuclear fuel (cladding temperature, fission gas driven pressure, strain and stress in the cladding, rod rupture, etc.) and how the separate effects interact in the complex integrated manner. The codes are under constant...
Content type: Publications -
2014:51 Report from SSM’s scientific council on ionizing radiation within oncology, 2013. MR in radiotherapy - an important step towards personalised treatment?
Imaging is important for radiotherapy and the development of new imaging modalities is closely linked to the evolution of modern radiotherapy. The implementation of magnetic resonance imaging (MRI) in modern radiotherapy holds great promise for the future but the scientific council emphasizes that it must be carefully monitored in order to minimize the introduction of new risks, violating...
Content type: Publications -
2014:26 Improved reference and relative dosimetry of small radiation therapy photon beams
Data tables on detector corrections for beam output measurements are provided for a large number of detectors (small air and liquid ionization chambers, silicon diodes, TLD and alanine) manufactured by major vendors, for 6 MV photons from clinical accelerators and for two Leksell Gamma Knife® models. They have been calculated with the PENELOPE Monte Carlo system at an uncertainty of 0.1%.
Content type: Publications -
2014:38 Technical Note, Detailed assessment of radionuclide Kd-values for the geosphere-main review phase
2926 kB...
Content type: Documents -
2014:35 Technical Note, Modelling comparison of alternative biosphere models with LDF models and evaluation of selected parameter values used in the biosphere dose assessment - Main review phase
4277 kB...
Content type: Documents -
2014:32 Technical Note, Assessment of the derivation and use of distribution coefficients and concentration ratios – Main Review Phase
1420 kB...
Content type: Documents -
2014:30 Modelling Approaches to C-14 in Soil-Plant Systems and in Aquatic Environments
3102 kB...
Content type: Documents -
2014:29 Technical Note, Independent Modelling of Radionuclide Transport, Evaluation of Colloid Transport Modelling – Main Review Phase
1357 kB...
Content type: Documents -
2014:23 Technical Note, Workshop on Rock Mechanics Issues and their Implications for Groundwater Flow – Main Review Phase
2366 kB...
Content type: Documents