Sök

Din avgränsning ger 411 träffar.

Sortera på:

Relevans Datum
  • 2019:16 SSM’s external experts’ reviews of SKB’s safety assessment SR-PSU

    Diff), or surrounded by void space (No Grout). The Min Ratio is No Grout ÷ Grout. The Max Ratio is No Grout ÷ Grout, No Diff (except for Se-79, where Min and Max are reversed). Radionuclide Peak radionuclide ... radionuclide flux per package (Bq/y) Ratio Grout Grout, No Diff No Grout Min Max C-14_org 9.11E+02 1.10E+03 6.20E+02 0.6 0.7 C-14_inorg 8.13E+01 1.40E+02 1.29E+03 9.2 15.9 Cl-36 3.76E+00 5.41E+00 3.64E+00...

    Innehållstyp: Dokument
  • 2003:43 Development of an Estimating Procedure for the Annual PLAN Process - with Special Emphasis on the Estimating Group (pdf, 542 kB)

    additions to other items, are transformed from a triple estimate (min, most likely, max) to their mean values, m, using the approximate formula: (min + 2.9 x likely + max)/4.9. The uncertainty is most efficiently ... efficiently measured as the standard deviation, s = (max – min)/4.65. The relative standard deviation, s/m, is applied where an item consists of more than one factor. The mean, M, of the total is then calculated...

    Innehållstyp: Dokument
  • 2005:23 DECOVALEX III PROJECT Thermal-Chemical Modeling of the Yucca Mountain Project Drift Scale Test

    exponent and the variable A is the reactive surface area expressed in units of watereral kgm / 2 min . The rate constant k (in mol m -2 s-1) is given as (Steefel and Lasaga 1994): ⎥⎦ ⎤⎢⎣ ⎡ ⎟⎠ ... equal to one. The variable A is the reactive surface area expressed in units of watereral kgm / 2 min . In the case of ideal solutions, the saturation index of the solid solution is calculated as the...

    Innehållstyp: Dokument
  • Backfill production report.pdf

    2618 kB ... set to be less then or equal to 1.7 l/min 100 m (based on 5 l/min in a 300 m long deposition tunnel) and the maximum point inflow less than or equal to 0.1 l/min /Sandén et al. 2008, Dixon et al. 2008a...

    Innehållstyp: Dokument
  • 2006:19 CCF-hantering vid beräkningar i grund PSA och PSA tillämpningar

    Common Load Model TI Testintervall MGL Multiple Greek Letter (CCF modell) MCS Minimal Cut Set MCUB Min Cut Upper Bound Modul- MCS MCS som baseras på oberoende moduler RDF Risk Decrease Factor RIF Risk ... 3. I förekommande fall beräknas sannolikhet för moduler exakt, vilket sker med hjälp av så kallad Min Cut Upper Bound (MCUB) och slutligen beräknas sannolikheten för topphändelsen. Topphändelsen sannolikhet...

    Innehållstyp: Dokument
  • 2006:29 Bränder i driftrum - Insatsplaner, släckteknik, risker

    Vatten (dimstråle) <130 Kv(130 000 v) 3 meter Vatten (300 min/l sluten stråle)* Oberoende spänning 14 meter * Strålrör med kapacitet över 300 min/liter skall inte användas i detta sammanhang Insatsplanering: ... manövrerbart mellan sluten och spridd stråle, kapaciteten på strålrören varierar mellan ~75 till 150 lit/min. Räddningstjänsterna på de olika verken har förutom tillgång till ovanstående också möjlighet att...

    Innehållstyp: Dokument
  • 2012:17 Technical Note, Corrosion of copper canister

    inflow is less than 0.01 l/min in 99.9% of the deposition holes in Forsmark, see SKB TR-06-102. Assume that some deposition holes will experience half that inflow rate, 0.005 l/min. This corresponds to an ... feature is the pinning effect of the entrapped oxide particles. After annealing the samples for 30 min at 850 °C, the general grain size was considerably larger, but the grains near the entrapped oxide...

    Innehållstyp: Dokument
  • Radiologiska konsekvenser – Clink och Clab.pdf

    5-1. Uppmätta utsläpp till luft från Clab. Nuklid Uppmätta utsläpp Clab 2003–2013 [Bq/år] Medel Min Max Mn-54 3,1E+04 1,7E+04 5,6E+04 Co-60 4,3E+06 5,6E+05 6,9E+06 Kr-85 8,6E+11 1,0E+10 1,7E+12 Sr-90 ... 5-2. Uppmätta utsläpp till vatten från Clab. Nuklid Uppmätta utsläpp Clab 2003–2013 [Bq/år] Medel Min Max H-3 1,6E+09 8,3E+07 9,9E+09 Mn-54 5,3E+05 1,5E+05 9,1E+05 Co-58 1,1E+06 3,1E+05 2,1E+06 Co-60...

    Innehållstyp: Dokument
  • 99:52 Corrosion of the Copper Canister in the Repository Environment

    finding such combinations. One example of work that should be performed is to determine possible max and min limits of critical concentrations, i.a. of chloride to be used in subsequent discussions of consequences ... referred data to represent a ground water on 500 m depth. Param. Dim. Selected value Min value Max value pH 8 9 Eh V -0.5 0.7 HCO3- mg/l 100 100 300 SO42- mg/l 8 5 500 Cl- mg/l 200...

    Innehållstyp: Dokument
  • Årsredovisning 2019

    exempel tillståndshavarnas och Regeringskansliets, syn på SSM och vår verksamhet. Analysen bekräftar min bild av medarbetarna men visar även att verksamheten har en utvecklingspotential. Jag bedömer att ... årliga undersökning av anseendet för svenska myndigheter 2019, där SSM kom på femte plats, förstärker min bild av SSM. Den 9 oktober invigde miljöminister Isabella Lövin våra nya lokaler i Katrineholm.

    Innehållstyp: Dokument