Visar 476 sökträffar på ”Min soltid”
-
Radiologiska konsekvenser – Clink och Clab.pdf
5-1. Uppmätta utsläpp till luft från Clab. Nuklid Uppmätta utsläpp Clab 2003–2013 [Bq/år] Medel Min Max Mn-54 3,1E+04 1,7E+04 5,6E+04 Co-60 4,3E+06 5,6E+05 6,9E+06 Kr-85 8,6E+11 1,0E+10 1,7E+12 Sr-90 ... 5-2. Uppmätta utsläpp till vatten från Clab. Nuklid Uppmätta utsläpp Clab 2003–2013 [Bq/år] Medel Min Max H-3 1,6E+09 8,3E+07 9,9E+09 Mn-54 5,3E+05 1,5E+05 9,1E+05 Co-58 1,1E+06 3,1E+05 2,1E+06 Co-60...
Innehållstyp: Dokument -
99:52 Corrosion of the Copper Canister in the Repository Environment
finding such combinations. One example of work that should be performed is to determine possible max and min limits of critical concentrations, i.a. of chloride to be used in subsequent discussions of consequences ... referred data to represent a ground water on 500 m depth. Param. Dim. Selected value Min value Max value pH 8 9 Eh V -0.5 0.7 HCO3- mg/l 100 100 300 SO42- mg/l 8 5 500 Cl- mg/l 200...
Innehållstyp: Dokument -
Årsredovisning 2019
exempel tillståndshavarnas och Regeringskansliets, syn på SSM och vår verksamhet. Analysen bekräftar min bild av medarbetarna men visar även att verksamheten har en utvecklingspotential. Jag bedömer att ... årliga undersökning av anseendet för svenska myndigheter 2019, där SSM kom på femte plats, förstärker min bild av SSM. Den 9 oktober invigde miljöminister Isabella Lövin våra nya lokaler i Katrineholm.
Innehållstyp: Dokument -
2006:19 CCF-hantering vid beräkningar i grund PSA och PSA tillämpningar
Common Load Model TI Testintervall MGL Multiple Greek Letter (CCF modell) MCS Minimal Cut Set MCUB Min Cut Upper Bound Modul- MCS MCS som baseras på oberoende moduler RDF Risk Decrease Factor RIF Risk ... 3. I förekommande fall beräknas sannolikhet för moduler exakt, vilket sker med hjälp av så kallad Min Cut Upper Bound (MCUB) och slutligen beräknas sannolikheten för topphändelsen. Topphändelsen sannolikhet...
Innehållstyp: Dokument -
2006:29 Bränder i driftrum - Insatsplaner, släckteknik, risker
Vatten (dimstråle) <130 Kv(130 000 v) 3 meter Vatten (300 min/l sluten stråle)* Oberoende spänning 14 meter * Strålrör med kapacitet över 300 min/liter skall inte användas i detta sammanhang Insatsplanering: ... manövrerbart mellan sluten och spridd stråle, kapaciteten på strålrören varierar mellan ~75 till 150 lit/min. Räddningstjänsterna på de olika verken har förutom tillgång till ovanstående också möjlighet att...
Innehållstyp: Dokument -
2003:09 Operational Readiness Verification, Phase 2: A Field Study at a Swedish NPP during a Productive-Outage
ladder, with the instructions in his pocket (I can’t 17 follow him there.. he comes back approx. 10 min later) 18 Reads one instruction, takes the two others in his hands, and goes and take away a tag. Signs ... and manoeuvre a valve (manually). Signs one instruction. 24 (etc.. this goes on for another 10-15 min) 25 He leaves the room, and goes to a room where the electrical equipment is. 26 Reads aloud 27 Puts...
Innehållstyp: Dokument -
Appendix 2 Dispersion and dose calculations
Rate from Plume Y/N Yes Gamma Dose Rate from Ground Y/N Yes Puff Released Every Min. 10 Outdata Every Min. 60 Trajectory Y/N No Local Scale Model Chain No Minimum Relative Concentration ... decays primarily into Ba-137m via beta decay, and thereafter to stable Ba-137 (half-life of approx. 3 min.). In this decay chain, the gamma emission takes place in connection with the decay of Ba-137m. In...
Innehållstyp: Dokument -
2019:04 Dosimetry in environments surrounding a laser-plasma accelerator
3824 kB ... most dominant nuclides are specified. Nuclide Half-life [min] Induced activity [mBq cm-3] Time after irradiation 10 sec 10 min 60 min 53mFe 2.58 5.0 0.4 0.00 53Fe 8.51 2.3 1.8 0.03 52V...
Innehållstyp: Dokument -
2014:21 Effects of additives on uranium dioxide fuel behavior
and a holding time of 1 h. Sweep gas was a high purity He+2%H2 mixture at a flow rate of 60 cm3/min. The β-activity, with an energy of 346 keV and half-life of 5.27 d, of released 133Xe during heating ... stoichiometry of the specimens during the experiment. The tests were conducted at a crosshead speed of 20 µm/min. corresponding to a strain rate of 0.09/h. The stress-strain curves presented in [101, 102] show that...
Innehållstyp: Dokument -
2017:05 Robust structural verification of pressurized nuclear components subjected to ratcheting, part two – stress-strain curves for cyclic elastoplastic analysis.
3004 kB ... the minimum stress-strain curves are obtained simply by scaling the average ones by the factor 0.2,min 0.2,/ moyR R . Doing so, the obtained applicable stress-strain curves for cyclic elastoplastic analysis...
Innehållstyp: Dokument