Din avgränsning ger 301 träffar.
-
SSMFS 2018:3 Strålsäkerhetsmyndighetens föreskrifter om undantag från strålskyddslagen och om friklassning av material, byggnadsstrukturer och områden
SSMFS 2018:3 har upphävt SSMFS 2011:2.
Innehållstyp: Publikationer -
SSMFS 2018:9 Strålsäkerhetsmyndighetens föreskrifter om godkända persondosimetritjänster
I SSMFS 2018:9 har ändringar förts in genom SSMFS 2021:2.
Innehållstyp: Publikationer -
2007:17 Spent Fuel Dissolution and Source Term Modelling in Safety Assessment
SKI is preparing to review the license applications being developed by the Swedish Nuclear Fuel and Waste Management Company (SKB) for a final repository for the geological disposal of spent nuclear fuel (SFL-2) in the year 2009. As part of its preparation, SKI is conducting a series of technical workshops on key aspects of the Engineered Barrier System (EBS) and spent fuel. This workshop...
Innehållstyp: Publikationer -
2007:12 Development of a constitutive model for the plastic deformation and creep of copper and its use in the estimate of the creep life of the copper canister
The copper-iron canister for disposal of nuclear waste in the Swedish Programme has a design life exceeding 100,000 years. Whilst the operating temperature and operating stress are modest, the very long design life does require that the likely creep performance of the canister should be investigated. Many studies have been carried out by SKB but these have all involved very short duration...
Innehållstyp: Publikationer -
2007:19 An Applied Study of Implementation of the Advanced Decommissioning Costing Methodology for Intermediate Storage Facility for Spent Fuel in Studsvik, Sweden with special emphasis to the application of the Omega code
The aim of this applied study has been to describe in a systematic way an appropriate methodological sequence for cost estimation of crucial parameters in decontamination and decommission processes. The work has been limited to older nuclear installations and facilities. Furthermore, it may be envisaged that the process of estimating the parameters of decommissioning is one of the main issues...
Innehållstyp: Publikationer -
2007:08 DECOVALEX-THMC - Task B
This report summarizes the work contributed to Phase 2 of Task B of the international DECOVALEX-THMC project, which took place during the period of March 2004 to May 2006. The Phase 2 work incorporated the use of a wide range of numerical models to simulate the failure of a number of intact rock core samples, from the APSE tunnel at Äspö HRL, as tested in uniaxial compression and other...
Innehållstyp: Publikationer -
2007:11 Review of Quality Assurance in SKBs Repository Research Experiments
SKB is preparing a license application for the construction of a final repository for spent nuclear fuel in Sweden. This application will be supported by the safety assessment SR-Site for the post-closure phase. As a preparation for SR-Site SKB has recently produced the SRCan safety assessment, which is currently in review. The assessment of long-term safety is based on a broad range of...
Innehållstyp: Publikationer -
2015:50 Assessment of structures subject to concrete pathologies (ASCET)
Many Nuclear Power Plants around the world are at the moment approaching, or in, their Long Term Operation stage of their operational phase. In addition, several NPPs have recently been carrying out uprate and life extension projects and comprehensive maintenance work including the exchange of components important to safety, in order to extend their lifetime. As a result, ageing management...
Innehållstyp: Publikationer -
2015:38 Evaluation of fatigue in austenitic stainless steel pipe components
Background Transferability of experimental results obtained for smooth test specimens under constant amplitude loading to realistic components subjected to variable amplitude loading is an important issue in the design against fatigue. There is a lack of experimental fatigue data for austenitic steel components and the present study is an important contribution to fill this gap. Objective The...
Innehållstyp: Publikationer -
2015:20 The effects of mild, acute hypoxia on cognitive performance
Room air with reduced oxygen levels that prevent materials to ignite and combust is a cost-effective and increasingly popular fire prevention method. For system safety reasons, the effects of hypoxia, that is, the lack of sufficient oxygen (that is, less than 21% oxygen which is the approximate oxygen level of normal air), on cognitive performance of persons working under such conditions are...
Innehållstyp: Publikationer