Din avgränsning ger 2145 träffar.
-
2011:34 Evolution of hydrogen by copper in ultrapure water without dissolved oxygen
stainless steel vessel plays no role in the experiment, which has been suggested previously (Johansson 2008). Gas analysis The results from the pressure gauge experiments showed that there is a clear ... production during corrosion of copper by water. Corrosion Science 53 310-319. Johansson, L. G. (2008) Comment on "Corrosion of copper by water" [Electrochemical and Solid- State Letters, 10(11), C63-C67...
Innehållstyp: Dokument -
2005:32e Safety and Radiation Protection at Swedish Nuclear Power Plants 2004
411 kB ... activity as well as achieving a high level of quality in its safety work. Furthermore, the Ordinance (1988:523) with instructions for SKI, stipulates that SKI shall follow developments in the nuclear energy...
Innehållstyp: Dokument -
2013:29 Regulatory Approaches in Nuclear Power Supervision
2612 kB ... WLOOV\QVYHUNVDPKHW SSM 2013:29 Huvudsakliga resultat Tillsyn är en iterativ och dynamisk process som använder olika kombinationer av angreppssätt som redskap för att fånga in ... VRPNRPSOHWWHUDQGHYHUNW\JRFKLQWHVRPNRQNXUUHUDQGHYHUNW\J Alla angreppssätten tillämpades och bedömdes vara an- vändbara $OODDQJUHSSVVlWWHQWLOOlPSDGHVRFKEHG|PGHVYDUDDQYlQGEDUDDYGHIOHVWD...
Innehållstyp: Dokument -
2019:24 SSM's external experts' review of SKB's analysis of long-term safety of 1BMA (SFR)
Swedish Nuclear Fuel and Waste Management Co.): Stockholm, Sweden. December 2013 SKB. 2013. “Låg- och medelaktivt avfall i SFR, Referensinventarium för avfall 2013.” Report R-13-37. Svensk Kärnbränslehantering ... form. Table 6-2 defines hydraulic conductivities used in flow modelling SKB R-13-37, 2013: Låg- och medelaktivt avfall i SFR, Referensinventarium för avfall 20 6 Description of average inventory...
Innehållstyp: Dokument -
2009:27 Analysis Strategy for Fracture Assessment of Defects in Ductile Materials
6858 kB ... Available procedures for flaw assessments, such as the ASME XI code and the R6 procedure [Milne et al, 1988] treat this issue differently. For instance, the ASME XI code does not consider weld-induced residual...
Innehållstyp: Dokument -
2005:20 DECOVALEX III PROJECT Modelling of FEBEX In-Situ Test
3981 kB ... radar measurements performed at the Grimsel Rock Laboratory in October 1985. NAGRA, NTB 87-13, Feb. 1988. Fierz T. FEBEX Instrumentation of BOUS 85.001 and 85.002, FBX 95.001 and 95.002 radial boreholes...
Innehållstyp: Dokument -
2004:31 Analysis of Weld Fabrication Flaws in High-Level Radioactive Waste Disposal containers (pdf 1 MB)
1055 kB ... commercial companies as gamma sources (Tschoepe et al. 1994). One of these capsules failed during 1988 as a result of its use in environmental conditions that were drastically different from those for...
Innehållstyp: Dokument -
2014:26 Improved reference and relative dosimetry of small radiation therapy photon beams
Vatnitsky, S., A new formalism for reference dosimetry of small and nonstandard fields, Med. Phys. 35 (2008) 5179-86. [2] Andreo, P., Burns, D.T., Hohlfeld, K., Huq, M.S., Kanai, T., Laitano, F., Smyth ... Dosimetric characterization of CyberKnife radiosurgical photon beams using polymer gels, Med. Phys. 35 (2008) 2312-20. [25] Pantelis, E., Moutsatsos, A., Zourari, K., Kilby, W., Antypas, C., Papagiannis...
Innehållstyp: Dokument -
2005:61 Review and Assessment of SCC Experiments with RPV Steels in Oskarshamn 2 and 3 (ABB Report SBR 99-020)
2227 kB ... [mm] No Martensite at the FL Martensite at the FL -6 -5 -4 -3 -2 -1 0 1 2 3 4 5 6 180 200 220 240 260 280 300 320 Low-Alloy SteelInconel 182 Vi ck er s H ar dn es s H V0 .0 5 Distance...
Innehållstyp: Dokument -
2010:46 Development of the PRO-LOCA Probabilistic Fracture Mechanics Code, MERIT Final Report
inspection. SSM 2010:46 Project information Project leader at SSM: Björn Brickstad Project number: SSM 2008/37 Project Organization: Battelle Columbus has managed the project with Paul Scott as the project ... QA and the overall QA for PRO-LOCA are not to the level required by ASME NQA-1. Part I of NQA-1-2008, Quality Assurance Requirements for Nuclear Facility Applications, is organized as 18 separate requirements...
Innehållstyp: Dokument