Sök

Din avgränsning ger 87 träffar.

Sortera på:

Relevans Datum
  • 2011:34 Evolution of hydrogen by copper in ultrapure water without dissolved oxygen

    One result from this research was that the experimental difficulties of repeating Hultqvist and co-workers work are considerable and were initially underestimated. The main challenge was to obtain satisfactory tightness of all connectors involved in the experimental set-up. The problems with leakage resulted in that the research program originally planned for in this project had to be reduced...

    Innehållstyp: Publikationer
  • Patienter får fel radiofarmaka

    Under 2011 har Strålsäkerhetsmyndigheten mottagit anmälningar från fyra sjukhus om missöden där patienter har administrerats fel radiofarmaka i samband med diagnostiska undersökningar. I samtliga fall har personalen missat någon av de kontroller som finns från beredning av radiofarmaka till administration. De inblandade hade olika lång erfarenhet...

    Innehållstyp: Artiklar
  • Omgivande elektronisk utrustning ger störningar i röntgenbilder

    Trådlösa detektorer  användes vid röntgenbildtagning på ett behandlingsrum på en tandvårdsklinik. Annan elektronisk utrustning gav återkommande störningar i röntgenbilder vilket medförde att bilderna fick tas om. I andra behandlingsrum hade tandvårdskliniken röntgensensorer anslutna med kabel, och där hade aldrig dessa...

    Innehållstyp: Artiklar
  • Ofrivillig genomlysning vid ortopedoperation

    Under en operation på ortopedkliniken kom av misstag en exponeringsutlösande pedal till genomlysningsutrustningen i kläm. Den sövda patienten genomlystes i 4 minuter och 55 sekunder innan utrustningens larm utlöstes och personalen i operationssalen upptäckte vad som skett och stängde av utrustningen. Personalen som befann sig i operationssalen bar vid tillfället...

    Innehållstyp: Artiklar
  • Felaktigt kalibreringscertifikat levererat med Ir-192 källa

    Vid rutinmässigt Ir-192 källbyte vid en brachyterapienhet upptäckte ansvarig sjukhusfysiker en signifikant skillnad på 7,5 procent mellan tillverkarens certifierade dosrat och kontrollmätt dosrat, vilket överskrider den osäkerhet tillverkaren uppger och de toleransgränser sjukhuset har.

    Innehållstyp: Artiklar
  • Bristande lokal utbildning ledde till onödig bildtagning

    En röntgensjuksköterska tog ett stort antal onödiga bilder vid en höftundersökning på en pojke. Sköterskan i fråga var en så kallad stafettsjuksköterska som inte hade fått någon lokal handhavande- eller strålskyddsutbildning innan hon fick börja arbeta. Hon fick inte heller den hjälp hon efterfrågade av sina...

    Innehållstyp: Artiklar
  • 2011:33 Mathematical modelling of ultrasonic testing of components with defects close to a non-planar surface

    The report describes work that has been performed in order to model ultrasonic testing of components that contain a defect close to a non-planar surface. The studies have been performed in both 2D and 3D, and in 2D in both the anti-plane (SH) and the in-plane (P-SV). The results show that the presence of a non-planar back wall can reduce the detectability of defects close to the surface. The...

    Innehållstyp: Publikationer
  • 2011:32 The Euratom Treaty v. Treaties of the European Union: limits of competence and interaction

    Generally regulation under the Euratom Treaty could be divided into two main groups: areas explicitly regulated by the Euratom Treaty (promotion of research and dissemination of knowledge; health and safety; encouragement of investment; supplies; safeguards; the nuclear common market) and areas which are in the competence of the Euratom Community, but are not laid out in the Euratom Treaty (...

    Innehållstyp: Publikationer
  • 2011:10e Review and evaluation of the Swedish Nuclear Fuel and Waste Management Company’s RD&D Programme 2010. Statement to the Government and summary of the review report

    In accordance with Section 25 of the Ordinance (1984:14) on Nuclear Activities (Nuclear Activities Ordinance), the Swedish Radiation Safety Authority (SSM) shall review and assess the research, development and demonstration programme (RD&D programme) that the reactor licensees are obligated to establish in accordance with the Act (1984:3) on Nuclear Activities (Nuclear Activities Act).

    Innehållstyp: Publikationer
  • 2011:31 Allocation of Decommissioning and Waste Liabilities

    A crucial task for the present generations is to ensure that environmental liabilities are identified sufficiently well so that it may be possible to accumulate the corresponding necessary financial assets in the Swedish Nuclear Waste Fund. Adequate funding will provide forthcoming generation’s with the financial means to decommission and dismantle older nuclear facilities that are part of...